SUNPAL Valve Regulated Lead Acid (VRLA) batteries can be stored for up to 6 months at 25℃ and then recharging is recommended. Monthly Self-discharge ratio is less than 3% at 25℃.Please charged batteries before using.
Container Material
A.B.S. UL94-HB, UL94-V0 Optional.
Constant Current Discharge Characteristics : A(25℃)
F.V/Time
15MIN
30MIN
1HR
2HR
4HR
8HR
10HR
20HR
1.60V
164.2
110.0
67.1
40.1
22.7
12.8
10.8
6.60
16.5V
160.8
109.1
66.8
39.8
22.6
12.7
10.7
6.36
1.70V
158.3
108.4
66.1
39.5
22.5
12.6
10.6
6.18
1.75V
152.5
106.7
65.5
39.2
22.3
12.5
10.5
6.00
1.80V
142.2
103.0
64.0
38.5
21.8
12.3
10.4
5.64
1.85V
129.0
97.4
60.8
36.8
20.7
11.8
10.1
5.40
Constant Power Discharge Characteristics : WPC(25℃)
F.V/Time
15MIN
30MIN
1HR
2HR
4HR
8HR
10HR
20HR
1.60V
301
209
129
78.8
45.2
25.5
21.6
11.7
16.5V
296
207
129
78.4
45.1
25.4
21.5
11.5
1.70V
293
207
128
78.0
45.0
25.2
21.3
11.3
1.75V
283
204
127
77.4
44.6
25.0
21.1
11.0
1.80V
264
198
124
76.4
43.6
24.6
20.8
10.8
1.85V
241
188
119
73.6
41.5
23.6
20.2
10.2
Certifications
ISO14001 ISO9001 GB/T 28001
CE CNAS MSDS
Our Factory
Project Cases
Professional Packing